Availability: | |
---|---|
Quantity: | |
KPG313C
KING POWER
8502120000
Genset model: King Power/KPG313C | Installation Method: Fixed |
Fuel type: Diesel | Cooling Method: Water Cooling |
Conditions of use: Land use | Usage: Common/standby units |
Excitation Mode: AC Rotating Exciter | HS code: 8502120000 |
Output Type: AC Three Phase | Stroke: Four Stroke |
Trademark: King Power | Out-put Power(KW/KVA): 250/313 |
Origin: Shenzhen, China | Dimension(MM):3530*1120*1980 |
Sound Level(DB): 60-105 | Gross weight(KGS):3327 |
Speed(RPM): 1500/1800 | Engine brand&Model: Cumins/NT855-G1A |
Alternator brand: Robot/Stamford/Marathon/Leroy-somer | |
Advantage: Anti-Vibration, Fuel-saving, high Efficiency | |
Package: Ply-wood/Film/EPE packing | |
Warranty Period:12 months after shipment or 1000 working hours. |
Accessory list for Open type Diesel Gen-set
Item | Name and spec | Quantity | Remark |
1 | Diesel engine | 1 set/ Genset | installed on the genset |
2 | alternator | 1 Pc/ Genset | installed on the genset |
3 | radiator | 1 Pc/ Genset | installed on the genset |
4 | Control panel | 1 Pc/ Genset | installed on the genset |
5 | Fuel tank | 1 Pc/ Genset | Accessories |
6 | Bellows | 1 set/ Genset | Accessories |
7 | Muffler | 1 set/ Genset | Accessories |
8 | Elbow | 1 set/ Genset | Accessories |
9 | Flange | 1 set/ Genset | Accessories |
10 | Flange gasket | 1 set/ Genset | Accessories |
11 | Shock-proof rubber | 1 set/ Genset | Accessories |
12 | Document with Genset | 1 set/ Genset | Accessories |
13 | Tools | 1 set/ Genset | Accessories |
14 | MCCB | 1 set/ Genset | installed on the genset |
15 | Smoke pipe | 1 Pc/ Genset | Accessories |
16 | Battery floating charger | 1PC/ Genset | installed on the genset |
Genset model: King Power/KPG313C | Installation Method: Fixed |
Fuel type: Diesel | Cooling Method: Water Cooling |
Conditions of use: Land use | Usage: Common/standby units |
Excitation Mode: AC Rotating Exciter | HS code: 8502120000 |
Output Type: AC Three Phase | Stroke: Four Stroke |
Trademark: King Power | Out-put Power(KW/KVA): 250/313 |
Origin: Shenzhen, China | Dimension(MM):3530*1120*1980 |
Sound Level(DB): 60-105 | Gross weight(KGS):3327 |
Speed(RPM): 1500/1800 | Engine brand&Model: Cumins/NT855-G1A |
Alternator brand: Robot/Stamford/Marathon/Leroy-somer | |
Advantage: Anti-Vibration, Fuel-saving, high Efficiency | |
Package: Ply-wood/Film/EPE packing | |
Warranty Period:12 months after shipment or 1000 working hours. |
Accessory list for Open type Diesel Gen-set
Item | Name and spec | Quantity | Remark |
1 | Diesel engine | 1 set/ Genset | installed on the genset |
2 | alternator | 1 Pc/ Genset | installed on the genset |
3 | radiator | 1 Pc/ Genset | installed on the genset |
4 | Control panel | 1 Pc/ Genset | installed on the genset |
5 | Fuel tank | 1 Pc/ Genset | Accessories |
6 | Bellows | 1 set/ Genset | Accessories |
7 | Muffler | 1 set/ Genset | Accessories |
8 | Elbow | 1 set/ Genset | Accessories |
9 | Flange | 1 set/ Genset | Accessories |
10 | Flange gasket | 1 set/ Genset | Accessories |
11 | Shock-proof rubber | 1 set/ Genset | Accessories |
12 | Document with Genset | 1 set/ Genset | Accessories |
13 | Tools | 1 set/ Genset | Accessories |
14 | MCCB | 1 set/ Genset | installed on the genset |
15 | Smoke pipe | 1 Pc/ Genset | Accessories |
16 | Battery floating charger | 1PC/ Genset | installed on the genset |
Genset features
1. Engine and alternator shall be mounted on a same frame steel skid.
2. Built-in damper for anti-vibration.
3. World-famous diesel engine brand.
4. World-famous AC alternators brand.
5. Intelligent and reliable control module.
6. Full range protection function and alarm shutdown feature.
7. Supply of all the necessary spare parts.
8. High price performance ratio.
9. After-sale service centers located all over the world.
Alternator Feature
1. Brush-less, 4 poles, rotation magnet.
2. IP21-23) enclosure is standard for all industrial alternators.
3. The insulation system is Class H
4. Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.
5. Wide range of flange adapters and single bearing disc coupling.
6. Standard 2/3 pitch windings avoid excessive neutral currents
7. AVR auto voltage regulator, auto exciter, auto adjustment
Standard Accessory
Steel base frame, 3 meters smoke pipe, Exhaust silencer, Flanges, bellows, Battery and connecting wires, Operation manual and documents, load test report, water temperature sensor, oil-pressure sensor, air breakers, control panel, maintaining tools, etc.
Optional Accessory
Water-proof canopy, engine coolant and oil heater, Alternator space heater, heat exchanger, remote control system with RS232/485 communication interface, floating battery charger, fuel-water separator, daily or base fuel tank, ATS, VTS, paralleling system, synchronizer, moving trailer or wheels, sound-proof canopy, extra spare parts.
ATS System
If the generator set will be used as a standby power, the auto transfer switch (ATS) is necessary and essential. Because ATS can automatically transfer load from Mains power to generator set. In normal, when the Main power fails or voltage drops below 80% of the normal voltage, ATS will auto start standby generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reaches at rated speed, the ATS will transfer the load to standby generator sets automatically.
Genset features
1. Engine and alternator shall be mounted on a same frame steel skid.
2. Built-in damper for anti-vibration.
3. World-famous diesel engine brand.
4. World-famous AC alternators brand.
5. Intelligent and reliable control module.
6. Full range protection function and alarm shutdown feature.
7. Supply of all the necessary spare parts.
8. High price performance ratio.
9. After-sale service centers located all over the world.
Alternator Feature
1. Brush-less, 4 poles, rotation magnet.
2. IP21-23) enclosure is standard for all industrial alternators.
3. The insulation system is Class H
4. Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.
5. Wide range of flange adapters and single bearing disc coupling.
6. Standard 2/3 pitch windings avoid excessive neutral currents
7. AVR auto voltage regulator, auto exciter, auto adjustment
Standard Accessory
Steel base frame, 3 meters smoke pipe, Exhaust silencer, Flanges, bellows, Battery and connecting wires, Operation manual and documents, load test report, water temperature sensor, oil-pressure sensor, air breakers, control panel, maintaining tools, etc.
Optional Accessory
Water-proof canopy, engine coolant and oil heater, Alternator space heater, heat exchanger, remote control system with RS232/485 communication interface, floating battery charger, fuel-water separator, daily or base fuel tank, ATS, VTS, paralleling system, synchronizer, moving trailer or wheels, sound-proof canopy, extra spare parts.
ATS System
If the generator set will be used as a standby power, the auto transfer switch (ATS) is necessary and essential. Because ATS can automatically transfer load from Mains power to generator set. In normal, when the Main power fails or voltage drops below 80% of the normal voltage, ATS will auto start standby generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reaches at rated speed, the ATS will transfer the load to standby generator sets automatically.